GAS REQUIREMENTS
change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a
NOTE: When a LP unit is directly attached into a LP house system, the step down regulator MUST be used to reduce the supply pressure to a max. 14” W.C. and min. 11” W.C. to the grill regulator.
LOCATING GRILL/BUILT-IN CLEARANCES
INSULATED JACKET:
Do not build the Grill under unprotected combustible construction. If the Grill is to be placed into a combustible enclosure, an approved insulated jacket is necessary and is available from your dealer. Use only the DCS insulated jacket which has specifically been designed and tested for this purpose.
LOCATION:
When determining a suitable location take into account concerns such as exposure to wind, proximity to traffic paths and keeping any gas or electrical supply lines as short as possible. Locate the grill only in a well ventilated area. Never locate the grill in a building, garage, breezeway, shed or other such enclosed areas without an approved ventilation system. During heavy use, the grill will produce a lot of smoke. Ensure there is adequate area for it to dissipate.
IMPORTANT :
Gas fittings, regulator, and installer supplied
CLEARANCES TO COMBUSTIBLE CONSTRUCTION:
A Minimum of 12" from the sides and a minimum of 12" from the back must be maintained from the Grill above and below the cooking surface to adjacent vertical combustible construction.
CLEARANCES TO NON-COMBUSTIBLE CONSTRUCTION:
A minimum of 3" clearance from the back of the grill to