9

INSULATED JACKET:

Do not build the Grill under unprotected combustible construction. If the Grill is to be placed into a
combustible enclosure,an approved insulated jacket is necessary and is available from your dealer.
Use only the DCS insulated jacket which has specifically been designed and tested for this purpose.

LOCATION:

When determining a suitable location take into account concerns such as exposure to wind,proximity
to traffic paths and keeping any gas or electrical supply lines as short as possible. Locate the grill only
in a well ventilated area. Never locate the grill in a building, garage, breezeway,shed or other such
enclosed areas without an approved ventilation system. During heavy use, the grill will produce a lot
of smoke. Ensure there is adequate area for it to dissipate.
IMPORTANT:
Gas fittings, regulator,and installer supplied shut-off valves must be easily
accessible.

CLEARANCES TO COMBUSTIBLE CONSTRUCTION:

A Minimum of 12" from the sides and a minimum of 12" from the back must be maintained from the
Grill above and below the cooking surface to adjacent vertical combustible construction.

CLEARANCES TO NON-COMBUSTIBLE CONSTRUCTION:

A minimum of 3" clearance from the back of the grill to non-combustible construction is required for
the purpose of allowing the lid to open fully. It is desirable to allow at least 6" side clearance to non-
combustible construction above the cooking surface for counter space. If you’ll be using the rotisserie
option,the space is essential for motor and skewer clearance. The Grill can be placed directly adjacent
to non-combustible construction below the cooking surface.
LOCATIN G GRILL/BUILT-IN CLEARANCES
GAS REQUIREMENTS
change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1
equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must
be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet specified,as
applicable,for connection Type 1. If the appliance is stored indoors the cylinder must be disconnected
and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area out of
the reach of children.
NOTE:When a LP unit is directly attached into a LP house system,the step down regulator MUST be
used to reduce the supply pressure to a max.14”W.C. and min. 11”W.C. to the grill regulator.