13

INSTALLER FINAL CHECKLIST:

GRILL BURNER FLAME HEIGHT:

To access the grill burner air shutters first remove the valve panel by removing the four screws on the
corners of the valve panel. Remove the control knobs. Pull the valve panel outward while unplugging
the igniter. With a screw driver,loosen the lock-screw on the face of the air shutter. Light the burner
and adjust according to the directions above.

BURNER AIR ADJUSTMENT:

Each grill burner is tested and adjusted at the factory prior to shipment;however,variations in the local
gas supply or a conversion from one gas to another may make it necessary to adjust the burners. The
flames of the burners (except the rotisserie burner) should be visually checked and compared to that
of the drawing in Fig.07. Flames should be blue and stable with no yellow tips,excessive noise or
lifting. I f any of these conditions exist,check if the air shutter or burner ports are blocked by dirt,
debris,spider webs,etc. Proceed with air shutter adjustment. The amount of air which enters a burner
is governed by a sheet metal cup or disk at the inlet of the burner called an air shutter.It is locked in
place by a set screw which must be loosened prior to lighting the burner for adjustment.

WARNI NG: IMPORTANT!

Before lighting, inspect the gas
supply piping or hose prior to
turning the gas "on". If there is
evidence of cuts, wear, or
abrasion, it must be replaced
prior to use.

TO ADJUST:

1. Be careful as the burner may be very hot.
2. If the flame is yellow, indicating insufficient air,turn the airshutter counterclockwise to allow more
air to the burner.
3. If the flame is noisy and tends to lift away from the burner, indicating too much air,turn the air
shutter clockwise.
4. Once adjusted turn the burner off and reverse steps to reassemble.
Specified clearances main -
tained to combustibles.
Nylon straps removed from
burners.
All internal packaging
removed.
Knobs turn freely,bezels
centered.
Each burner lights satisfa-
torily,individually or with
adjacent burner lit.
Air shutters adjusted.
Adjustable low setting satis-
factory.
Drip pan in place properly
and sliding freely.
Pressure regulator
connected and set for 4.0"
W.C.Natural, 11.2" W.C.LP
gas.
Manual shut-off valve
installed and accessible.
Unit tested and free of leaks.
User informed of gas supply
shut-off valve location.
PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.
USER,PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
1/2"
3/8"
INSTALLER CHECKLIST/BURNER ADJUSTMENTS
FIG.07 Burner Flame Height