13
INSTALLER FINAL CHECKLIST:
GRILL BURNER FLAME HEIGHT:
To access the grill burner air shutters first remove the valve panel by removing it the same way as
described on page 12,section “Before Testing”.With a screw driver,loosen the lock-screw on the face
of the air shutter. Light the burner and adjust according to the directions below.
❏Specified 12”clearances
maintained to combustibles.
❏Verified proper enclosure
ventilation.
❏Nylon straps removed from
burners.
❏All internal packaging
removed.
❏Knobs turn freely,bezels
centered.
❏Each burner lights satisfac-
torily,individually or with
adjacent burner lit.
❏Air shutters adjusted.
❏Adjustable low setting satis-
factory.
❏Drip pan in place properly
and sliding freely.
❏Pressure regulator
connected and set for 4.0"
W.C.Natural, 11.2" W.C.LP
gas.
❏Manual shut-off valve
installed and accessible.
❏Unit tested and free of
leaks.
❏User informed of gas supply
shut-off valve location.
❏All radiants are assembled
(see page 15) and put in
place.
PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.
USER,PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
1-1/2"
3/8"
FIG.07 Burner Flame Height
Sealed Burner
INSTALLER CHECKLIST/BURNER ADJUSTMENTSFIG.09