GAS REQUIREMENTS

LP GAS HOOK UP (TYPE 1 OR QCC1 REGULATOR):

Grills orificed for use with LP gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. LP cylinder (Type 1). The LP tank is not included.

Connection: 1/2" NPT male with a 3/8" Flare adapter (included). LP Hose with a quick disconnect and

fittings are included. Operating pressure: 10.0" W.C.

To connect the LP regulator/hose assembly to the tank/valve assembly, first make sure the main valve on the tank is completely closed. Although the flow of gas is stopped when the Type 1 system is discon- nected as part of of its safety feature, you should always turn off the LP tank main valve (Fig.02) after each use and during transport of the tank or unit. Insert the regulator inlet into the tank valve and turn to the black coupler clockwise until the coupler tightens up. Do not overtighten the coupler. Turn the main tank valve on and turn the burner control valves on the unit to the “HI” position for about 20 seconds to allow the air in the system to purge, turn valves off and wait 5 minutes before attempting to light the burners.

To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn counter clockwise. The inlet will then disengage, remove the inlet from the tank valve opening if it has not already done so when it disengaged. Your local LP filling station should be equipped with the proper equipment to fill your tank.

LP TANK REQUIREMENTS:

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. Never use a cylinder with a damaged valve. Always check for leaks after every LP tank change. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT or CAN/CSA-B339) and designed for use with a Type 1 system only. Do not change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection Type 1. If the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.

NOTE: When an LP unit is directly attached into an LP house system, the step down regulator MUST be used to reduce the supply pressure to a max. 14” W.C. and min. 11” W.C. to the grill regulator.

Adapter 1/2 NPT

Bottom of unit

to 3/8 flare fitting

 

Do not put threading compound on these threads

LP Regulator hose assembly 10" W.C.

*Installation must conform with local codes or with the National Fuel Gas Code ANSI Z223.1 or the CAN/CGA- B149.2 Propane Installation Code

Threading compound must be resistant to LP gas

Type 1 Regulator

Main Valve

Type 1 Tank

FIG.02 LP Gas

8

Page 9
Image 9
DCS BGB30-BQR manual LP GAS Hook UP Type 1 or QCC1 Regulator, LP Tank Requirements

BGB30-BQR specifications

The DCS BGB30-BQR is a state-of-the-art gas monitoring and detection system, designed to ensure maximum safety and reliability in a variety of industrial environments. This advanced device integrates cutting-edge technologies and sophisticated features that make it a preferred choice for professionals in sectors such as oil and gas, manufacturing, and chemical processing.

At the heart of the BGB30-BQR lies its high-performance gas sensors, which are capable of detecting a wide range of hazardous gases including methane, propane, and hydrogen sulfide. These sensors utilize advanced electrochemical technology that allows for quick and accurate readings, ensuring that any potential gas leaks can be identified rapidly. The device is designed for real-time monitoring, providing continuous data to maintain safety in critical settings.

One of the standout features of the BGB30-BQR is its robust wireless communication capabilities. Equipped with built-in Bluetooth and Wi-Fi, the system allows for seamless integration into existing network infrastructures. This feature enables operators to access real-time data remotely via smartphones or tablets, empowering them to make informed decisions instantly. Additionally, the BGB30-BQR supports both local and cloud-based data storage, ensuring that historical data is available for analysis and regulatory compliance.

The BGB30-BQR is also built with durability in mind. Its rugged design meets tough environmental standards, making it suitable for both indoor and outdoor applications. With an IP68 rating, the device is resistant to dust and water ingress, ensuring longevity in challenging conditions.

Another significant characteristic of the BGB30-BQR is its user-friendly interface. The device comes with an intuitive LCD display that shows real-time gas level readings, battery status, and alerts for immediate troubleshooting. Furthermore, the device includes customizable alarm settings that can be tailored to suit specific operational requirements, ensuring prompt responses to any sign of danger.

In conclusion, the DCS BGB30-BQR gas monitoring system exemplifies innovation in safety technology. With its advanced sensing capabilities, robust communication features, durable construction, and user-friendly design, it stands out as a reliable solution for gas detection in various industrial applications. Investing in the BGB30-BQR not only enhances workplace safety but also boosts operational efficiency by providing critical data when it matters most.