DCS CT-365GN, CT-365BL manual GAS Hook UP

Models: CT-365GN CT-365BL

1 22
Download 22 pages 9.5 Kb
Page 15
Image 15

Installation Instructions

GAS HOOK UP:

Operating Gas: Set for NATURAL, adjustable for LPG by a qualified technition.

Pressure Inches W.C.: 10.0”-LPG/4.0”-Natural Gas

Verify the type of gas supplied to the location.The cooktop is shipped from the factory set up for Natural Gas and can be modified for LPG. A manual valve must be installed external to the appliance, in an accessible location from the front for the purpose of shutting off the gas supply. Make sure the gas supply is turned off at the wall valve before connecting the appliance. The gas supply connections should be made by a qualified technician and in accordance with local codes or ordinances.

Locate Gas Supply and Electrical Supply, referring to the illustrations below.

Flex Line to Cooktop

! Manual Shut-Off

Valve must be

Easily Accessible

2" Maximum Protrusion from Wall for Gas Supply

COUNTER TOP

Installer supplied shut-off valve must be easily accessible inside cabinetry

4 FOOT POWER CORD

GAS SUPPLY

ELECTRIC SUPPLY

14

Page 15
Image 15