DCS CT-365BL, CT-365GN manual Power Requirements, Recommended Grounding Method

Models: CT-365GN CT-365BL

1 22
Download 22 pages 9.5 Kb
Page 16
Image 16

Installation Instructions

POWER REQUIREMENTS:

120 VAC, 60 Hz., single phase.

CT-365: 0.10 Amp. Max.

(Use 15 Amp. Circuit minimum)

Always disconnect the electric supply cord from the wall outlet or service disconnect before servicing this appliance.

Observe all governing codes and ordinances when grounding, in the absence of which, observe National Electrical Code ANSI/NFPA No. 70-1990.

RECOMMENDED GROUNDING METHOD:

This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades). It must be plugged into a mating grounding, type receptacle, connected to a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the installer or user to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances the receptacle replacement shall be in accordance with the National Electrical Code. THE THIRD GROUND PRONG SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. The electrical supply must be a 120 volt, 60 Hz single phase, 15 AMP circuit.The power receptacle must be a NEMA 5-15R device to accept the three prong plug supplied with the unit.

THIRD GROUND PRONG

15

Page 16
Image 16
DCS CT-365BL, CT-365GN manual Power Requirements, Recommended Grounding Method