Reply by speaking in the direction of the microphone in the AOM unit.

Adjust the volume with the VOL keys on the AOM unit.

Press the SPK or the MONITOR key on the AOM to disconnect the an- nouncing party.

NOTES:

1.Executive off-hook voice announce can only be accomplished when an AOM is attached to your phone.

2.If the MUTE key on the AOM is lit, you must press the AOM’s SPK key to answer the OHVA call.

OHVA BLOCK

Your keyset can be programmed with an OHVA Block (BLOCK) key. Pressing this key will prevent anyone from making an OHVA to you until you press the button again and cancel the blocking.

OHVA REJECT

Your keyset can be programmed with an OHVA Reject (REJECT) key. Pressing this key while receiving an OHVA call will disconnect the voice announcing party and return you to your original call.

IN GROUP/OUT OF GROUP

If your keyset is assigned to a station ring group, you can remove your keyset from the group and then put it back in. While you are out of the group, you can receive calls to your extension number but not calls to the group number. If you have an IN/OUT key:

Press the IN/OUT key. It will light red when your keyset is in the group.

Press the IN/OUT key again to exit the group and turn the light off. Repeat as necessary.

If you do not have an IN/OUT key:

Dial the IN/OUT access code number __________ plus 0 to exit the group or 1 to enter the group.

NOTE: If the Hot Keypad feature has been turned off, you must first lift the handset or press SPK or the MONITOR key.

The IN/OUT key can include an extender to indicate the specific group that this key will affect. This means that if you are in multiple groups, you can decide for which groups you will receive calls.

CUSTOMIZING YOUR KEYSET

AME BGM

This feature selects whether a station using Answer Machine Emulation will hear their personal greeting or BGM while callers are listening to the personal greeting. A BGM source must be selected for this to work. This feature only applies if there is a CADENCE card installed in the system and your keyset has a programmed AME key.

While the handset is on-hook, press TRSF and then dial 110.

Press 091 to turn on AME BGM or 090 to turn it off.

Press TRSF to store your selection.

AME PASSWORD

This feature allows people using the AME feature to enable password protec- tion. This will prevent unauthorized people from listening to your messages be- ing left. The passcode is the same as your station passcode. This feature only applies if there is a CADENCE card installed in the system and your keyset has a programmed AME key.

With the handset on-hook, press TRSF and then dial 110.

Dial 101 to turn on AME BGM or 100 to turn it off.

Press TRSF to store your selection.

SELECT RING TONE

Each keyset user can select any one of eight ring frequencies:

While on-hook, press TRSF and then dial 111.

Dial 18or press the UP and DOWN keys to hear each tone.

When you hear the tone that you prefer, press TRSF to save it.

NOTE: Specific lines or stations may be programmed to ring with a different tone than what you have selected for you keyset.

CHANGE YOUR PASSCODE

From the factory, your station passcode is 1234. You can change your station passcode whenever you desire.

While on-hook, press TRSF and then dial 101.

Dial your old passcode.

Dial a new passcode (must be four characters).You can use 09.

36

37

Page 21
Image 21
DCS LCD 24B, STD 24B, 7B, BASIC 12B, LCD 12B manual Customizing Your Keyset

LCD 24B, 7B, STD 24B, LCD 12B, BASIC 12B specifications

The DCS STD 24B, 7B, BASIC 12B, LCD 24B, and LCD 12B are advanced digital control systems designed to enhance operational efficiency in various applications, including industrial automation and process control. Each model offers distinct features and technologies tailored to meet the needs of diverse environments.

The DCS STD 24B is characterized by its highly scalable architecture, allowing for seamless integration into existing systems. This model supports up to 24 I/O points, making it ideal for medium-sized applications. Its user-friendly interface, equipped with a touch screen, allows operators to easily navigate through complex processes. Additionally, it features robust connectivity options, including Ethernet and serial communication, ensuring reliable data exchange between devices.

The DCS 7B stands out with its advanced data processing capabilities. Equipped with a high-performance microcontroller, this system can handle complex algorithms and perform real-time data analysis. The 7B model also emphasizes safety, incorporating multiple redundancy features and built-in diagnostics to prevent system failures. Its compact design makes it suitable for installation in space-constrained environments.

The BASIC 12B model is designed for entry-level applications, providing essential control features at a competitive price point. It supports up to 12 I/O points and comes pre-configured for easy setup, making it an excellent choice for small-scale projects. Despite its simplicity, the BASIC 12B offers essential monitoring capabilities, enabling operators to track system performance effectively.

The LCD 24B and LCD 12B models incorporate advanced liquid crystal display technology for enhanced visibility and user interaction. The LCD 24B is designed for comprehensive process visualization, featuring bright, high-resolution graphics that display critical data in real-time. This model supports extended functionalities, including alarm management and remote monitoring.

Conversely, the LCD 12B focuses on core monitoring and control tasks while ensuring easy readability. Both LCD models are built with durable materials, providing additional robustness in demanding environments. They feature intuitive interfaces that simplify operation for users while ensuring that critical parameters are easily accessible.

In conclusion, the DCS STD 24B, 7B, BASIC 12B, LCD 24B, and LCD 12B offer a diverse range of features, technologies, and characteristics, catering to various operational needs. With their emphasis on scalability, performance, and user-friendliness, these digital control systems are positioned to enhance efficiency and productivity across multiple sectors.