4.Is the problem resolved? Yes. End troubleshooting.

No. See Chapter 9, “Getting Help,” for instructions on obtaining technical assistance.

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

$￿￿￿￿￿

The system has two advanced cooling modules (ACMs). Each ACM contains two blowers, and each blower has its own fault LED, so there are two fault LEDs on the back of the ACM. Any one blower can fail without any danger of the PowerVault stor- age system overheating.

If the amber ACM fault indicator light is illuminated (see Figure 8-3) or the Dell OpenManage Array Manager program issues an ACM-related error message, follow the ACM troubleshooting procedure below.

￿￿￿￿￿￿￿￿￿$￿￿￿￿￿#￿￿%￿￿￿￿￿&￿￿'￿￿￿￿￿(()￿￿￿￿￿￿￿￿*￿￿"￿￿￿￿￿￿￿"+￿￿￿￿￿

To troubleshoot an ACM, perform the following steps:

1.Is one of the following events occurring?

￿Are both fault indicators lit on a single ACM?

￿Are fault indicators lit on both ACMs?

support.dell.com

Troubleshooting 8-11