4Record the IQN of the PowerVault MD3000i storage array in the "Configuration Worksheet" on page 77:

a Select the iSCSI tab, and then click Change Target Identification. b Record the iSCSI target name.

NOTE: The ISCSI Target Alias cannot be used by a host for booting.

5Record the iSCSI host port IP addresses of the RAID controllers in the "Configuration Worksheet" on page 77:

a Select the iSCSI tab and click Configure iSCSI Host Ports.

b Select each iSCSI host port from the drop down list. Record the IP address of the port to which the host system is configured to boot from. If the host system has redundant paths, select a port on a controller that is on a separate subnet.

6Use the iSCSI DOS utility located in the iSCSI\DOS directory on the media that shipped with the Intel NIC to flash the Intel NIC with the iSCSI

Boot PROM. For more instructions, see the Intel iSCSI Boot User Guide. Boot to a bootable MS-DOS®diskette drive or a bootable USB key, and run the iSCSI DOS utility using the following commands:

ISCSIUTL –ALL –FLASHENABLE ISCSIUTL –ALL –UP

For additional help, type ISCSIUTL –?at a command prompt.

7Boot to the Intel iSCSI Boot Setup menu. For more information, see the "Firmware Setup" section in the Intel iSCSI Boot User Guide.

a Configure one NIC as Primary.

b Enter the initiator name, IP address, subnet, and gateway of the host that you recorded in step 1 of "Configuring the PowerVault MD3000i Storage Array" on page 15.

c Enter the IQN and IP address of the target.

d Retain the default values of the port number as 3260 and LUN number as 0, unless you need to change them.

e Select OK and save the changes.

Instructions for Booting a New Host Using Intel NIC