4Open the iSCSI Software Initiator GUI to ensure that there are no entries in the Discovery tab or in the Persistent Targets tab.

5Open the Disk Management console and verify the iSCSI LUN is recognized.

6Replicate the operating system boot image from the local hard drive to an image then to the iSCSI LUN and then boot from the iSCSI LUN.

7Disable the local hard drive and boot from the iSCSI LUN.

Additional Information

If you are using two NICs — one as primary and one as the secondary boot NIC, ensure that they are configured to use separate subnets.

NIC teaming is not supported for iSCSI traffic on the host or on the PowerVault MD3000i storage array.

After the host is configured to use BFi, you can configure additional paths to other targets in the Microsoft iSCSI Software Initiator.

Do not log in to ports that were configured in the iSCSI boot BIOS, these logins are automatically performed through the NIC iSCSI boot firmware table.

Instructions to Configure BFi for Intel NIC