10Go to the BIOS menu, disable the local hard drive and reboot.

7Clone the operating system partition to the Fat32 partition (partition to image) or network share (disk to image).

8Reboot the host and boot into the operating system on the local hard drive.

9Launch Windows compatible cloning software such as Ghost32 application and write the image in Fat32 partition (or network share) to the remote LUN.

10Go to the BIOS menu, disable the local hard drive and reboot.

11During BIOS POST, press <Ctrl><s> to enter Broadcom MBA configuration menu.

12Press <Ctrl><k> to enter iSCSI boot configuration menu.

13Select the device from the list that was previously configured for iSCSI boot and press <Enter>.

14Select General Parameters from the menu and press <Enter>.

15Configure Boot to iSCSI target to Enabled as shown in Figure 4-2.

Figure 4-2. Configuring General Parameters