26 Hardware Installation
c
Turn off any expansion enclosure(s) in the affected system.
3
Cable the expansion enclosure(s) to the storage array.
4
Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status
LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that
the unit is ready:
If the status LEDs are solid amber, the storage array is still coming
online.
If the status LEDs are blinking amber, there is an error that can be
viewed using PowerVault MDSM.
If the status LEDs are solid blue, the storage array is ready.
c
After the storage array is online and ready, turn on any attached host
systems.
5
Using PowerVault MDSM, update all attached expansion enclosure
firmware if it is out of date:
a
From the EMW, select the enclosure that you want to update and
enter the
Array Management Window
(AMW).
b
Click
Advanced

Maintenance
Download

EMM Firmware
.
c
Select
Select All
to update all the attached expansion enclosures
simultaneously.
book.book Page 26 Sunday, September 11, 2011 10:24 PM