58 Appendix—Manual Configuration of iSCSI
NOTE: Before configuring the storage array, check the status icons on the
Summary tab to ensure that the enclosures in the storage array are in an Optimal
status. For more information on the status icons, see the Owner’s Manual at
support.dell.com/manuals.
Step 2: Configure the iSCSI Ports on the Storage Array
By default, the iSCSI ports on the storage array are set to the following IPv4
settings:
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask:
255.255.255.0 Port: 3260
Controller 0, Port 1: IP: 192.168.131.101 Subnet Mask:
255.255.255.0 Port: 3260
Controller 0, Port 2: IP: 192.168.132.101 Subnet Mask:
255.255.255.0 Port: 3260
Controller 0, Port 3: IP: 192.168.133.101 Subnet Mask:
255.255.255.0 Port: 3260
Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask:
255.255.255.0 Port: 3260
Table A-2. Initial Setup Tasks Dialog Box
Task Purpose
Rename the storage array To provide a more meaningful name than the
software-assigned label, Unnamed.
Set a storage array password To restrict unauthorized access. MDSM may ask
for a password before changing the
configuration or performing a destructive
operation.
Set up alert notifications
Set up e-mail alerts
Set up SNMP alerts
To notify individuals (by e-mail) and/or storage
enterprise management consoles, such as Dell
Management Console, (by SNMP) when a
storage array component degrades or fails, or an
adverse environmental condition occurs.
Configure a storage array To create virtual disks and map them to hosts.
book.book Page 58 Sunday, September 11, 2011 10:24 PM