NICD BATTERY CHARGER WITH RECONDITIONING FEATURE

MLPN: 45561 - 115V and 45562 - 230V

Transformer

Discharge

Cycle Switch

 

 

 

 

 

 

 

Red LED

 

 

 

 

Green LED

(Power)

 

 

 

 

(Charge Status)

 

 

 

 

 

 

Figure 7: Reconditioning

RECOMMENDED USE

How to Recondition

1.Place the scanner into the charge stand.

2.Push the stand tilt cup in the extreme down position to expose the hole for the discharge cycle switch.

3.Use a pin to push the discharge cycle switch located beneath the hole.

4.When the discharge mode is initiated the green LED flashes.

To maintain charge capacity, the NiCd batteries must be discharged fully before charging. We call this process reconditioning.

Recondition if:

The batteries were not used within 20 days

The batteries were not discharged (approximately two hours of continuous operation) at least once a week

Low battery indicators:

Both LED’s on the scanner blink

The scanner quietly beeps twice while scanning

Recondition once a week if:

The batteries do not get discharged for more than 20% (approximately ½ hour) of their capacity before recharging.

Recondition once every two weeks if:

The batteries do not get discharged for more than 50% (approximately 1 hour) of their capacity before recharging.

Note: The day to day usage of the NiCd batteries will determine the frequency of the discharges (reconditioning).

Charge StateCHG LED Status

Battery Absent

LED off

Charge Pending

LED on for 0.125sec, off for

1.375sec

 

Discharge-Before-

LED on for 1.375sec, off for

Charge

0.125sec

Fast-Charge

LED on

 

 

Charge Complete Top-

LED on for 0.125 sec, off for

Off

0.125sec

 

 