GAS SUPPLY:

GAS SUPPLY:

This appliance is suitable for use with Natural Gas or ULPG. (Check the “gas type” sticker attached to the appliance).

For Natural Gas the gas supply must be regulated to obtain a pressure of 1 kPa with the two semi-rapid (SR) burners operating.

For ULPG models connect the gas supply directly to the appliance test point adap- tor (supplied with the conversion kit) and ensure that the supply pressure is regulat- ed to 2.75 kPa.

Do NOT force the ”elbow“ rotation prior to loosening nut.

Do NOT over tighten the nut at the ”elbow“.

1.After connecting the gas supply, check the piping and connections for leaks using a soap and water solution. The presence of bubbles indicates a leak, tighten or replace connections as appropriate.

Warning: Do not use any naked flame to check for leaks.

2.The operation of the appliance MUST be tested before leaving.

3.Adjust the test point pressure or supply pressure to the value which is appropriate for the gas type.

4.Turn on the appliance gas controls and light each burner. Check for a well defined blue flame without any yellow tipping. If any abnormality is evident then check that the burner cap is located properly and the injector nipple is aligned correctly.

Figure 5a

 

Gas connection for

 

NATURAL GAS

 

Gas inlet pipe

 

Gasket

Test

Brass conical adaptor

point

(Thread tight: use

 

suitable seal)

 

Gas regulator

8

 

Figure 5b

Gas connection for

ULPG

Gas inlet pipe

Gasket

Brass conical adaptor

(Thread tight: use

suitable seal)

Test point adaptor

Test

point