5.Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position, the flame must not go out. If adjustment is required carry out the “minimum burner setting adjustment" procedure described below.

6.If satisfactory performance cannot be obtained, the installer shall check the installa- tion and notify the local gas supply authority for a gas supply problem, or if it is an appliance problem, our Customer Service Centre should be called to obtain the nearest authorized Delonghi Service Agent.

7.Where the appliance data plate cannot be easily read with the appliance in the installed position the duplicate data plate must be attached to adjacent surface and the duplicate ULPG conversion label should also be included where a ULPG conver- sion has been completed.

INSTALLATION WITH A FLEXIBLE HOSE ASSEMBLY

If this appliance has to be installed with a hose assembly, the installer shall refer to the network operator or gas supplòier for confirmation of the gas type, if in doubt.

The gas supply connection point shall be accessible when the appliance is installed.

Installation with a flexible hose assembly shall be carried out by using a hose with internal diameter of 16 mm minimum.

The thread connection shall be Rp 1/2" (ISO 7-1) male.

IMPORTANT WARNING: After connection the installer must check that the hose is not kinked, subjected to abrasion or permanently deformed.

The installer must check also that the hose is not near (or in contact) with any hot surfaces e.g. base of metal hotplate, underbench oven etc.

The hose assembly shall be as short as practicable and comply with relevant AS 5601/601 requirements.

IMPORTANT WARNING: The installer shall ensure the hose assembly is restrained from accidental contact with the flue outlet of an underbench oven.

TABLE FOR THE CHOICE OF THE INJECTORS

 

Natural gas

 

ULPG

 

 

 

 

 

 

 

 

 

Test Point Pressure [kPa]

 

1.0

 

2.75

 

 

Injector

 

Gas

Injector

 

Gas

 

BURNER

Orifice Dia.

 

Consumption

Orifice Dia.

 

Consumption

 

 

 

 

 

 

 

 

 

[mm]

 

[MJ/h]

[mm]

 

[MJ/h]

 

 

 

 

 

 

 

 

 

Auxiliary (A)

0.85

 

3.6

0.53

 

3.6

 

 

 

 

 

 

 

 

 

Medium-speed burner (SR)

1.12

 

6.3

0.70

 

6.3

 

 

 

 

 

 

 

 

 

Triple-ring burner (TR)

1.55

 

11.9

0.94

 

11.9