ASSEMBLING BLADE GUARD AND SPLITTER ASSEMBLY

DISCONNECT MACHINE FROM POWER SOURCE.

MAKE SURE BLADE IS NOT ATTACHED. IF IT IS, REMOVE THE SAW BLADE FROM THE SAW USING THE SUPPLIED WRENCHES.

1.Fasten the rear splitter mounting bracket (A) Fig. 15, to the rear trunnion on the back of the saw using the two 1/4”-20 x 3/4″ hex head screws (B), 1/4” flat washers and 1/4” lock washers. Place flat washers, then lock washers onto the screw, then insert them through the holes in the splitter mounting bracket and into the tapped holes in the trunnion. Do not completely tighten the two screws (B) at this time.

2.Raise saw arbor to its highest position.

3.Using a 12 mm wrench, remove hex head screw and large washer (C) Fig. 16 from the inside splitter mounting bracket.

4.Remove the outer arbor flange and leave the inner arbor flange (F) Fig. 16 on the arbor.

4.Use a straight edge to check to see if the top and bottom of the inside splitter bracket (D) Fig. 17 is aligned with the inner arbor flange (E).

A

B

Fig. 15

F

Fig. 16

D

E

Fig. 17

14

Page 14
Image 14