ADJUSTING BLADE ALIGNMENT
BLADE ALIGNMENT IS FACTORY SET
AND SHOULD NOT NEED ADJUSTMENT. ADJUSTING BLADE ALIGNMENT IN THE FIELD IS A DIFFICULT AND
DISCONNECT MACHINE FROM POWER SOURCE.
1.Lower blade. Remove blade guard and table insert. With a 1/2″ wrench, slightly loosen the 4 front and rear trunnion mounting bolts. NOTE: Two trunnion mounting bolts (E) Fig. 37 are shown as looking up inside side of saw.
2.Move the trunnion assembly in the desired direction. Tap gently with rubber mallet if necessary.
3.To check blade alignment, follow section “CHECKING BLADE ALIGNMENT” procedure until proper alignment is achieved. Tighten 4 trunnion bolts (E) Fig. 37.
4.Check blade alignment again after tightening bolts to confirm alignment. If alignment is off, loosen the 4 trunnion bolts (E) and repeat the above steps until proper alignment is achieved with bolts fully tightened.
5.Install table insert, blade guard, and lower blade before reconnecting power source.
BACKLASH ADJUSTMENTS
DISCONNECT MACHINE FROM
POWER SOURCE.
After a period of extended use, if any play is detected in the blade raising or blade tilting mechanisms, remove the blade and make the following adjustments:
ADJUSTING BLADE RAISING MECHANISM - Loosen locknut (A) Fig. 38, and turn eccentric sleeve (B) until all play is removed. Tighten locknut (A) while holding sleeve in place.
ADJUSTING BLADE TILTING MECHANISM - Loosen locknut (C) Fig. 38, and turn eccentric sleeve (D) until all play is removed. Tighten locknut (C) while holding sleeve in place.
E
Fig. 37
C
D
A B
Fig. 38
20