ADJUSTING MITER GAGE SLOT PARALLEL WITH SANDING DISC

1.DISCONNECT MACHINE FROM POWER SOURCE.

2.Using a combination square (A) in the miter gage slot, check the distance from the slot to each end of the sanding disc, as shown in Figs. 32 and 33. This distance should be the same.

3.If an adjustment to the table is necessary, loosen the three screws (B) Fig. 34, that fasten the table to the table mounting bracket and trunnion and adjust the table accordingly - then tighten the three screws (B).

MITER GAGE

A miter gage (A) Fig. 35, is supplied with your machine and is used with the disc table. The miter gage body (A) can be rotated right or left for angle or miter sanding by loosening lock knob (B), rotate miter gage body and tighten lock knob (B).

A

Fig. 32

A

Fig. 33

B

Fig. 34

A

B

Fig. 35

14

Page 14
Image 14
Delta SA446 instruction manual Adjusting Miter Gage Slot Parallel with Sanding Disc