Desa 103426-01 Connecting To Gas Supply, Unvented Natural Gas Log Heater, Installation, Continued

Models: 103426-01

1 32
Download 32 pages 31.72 Kb
Page 10
Image 10
CONNECTING TO GAS SUPPLY

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 23.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Manual background CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

A.G.A. Design-Certified

Manual Shutoff Valve With

1/8" NPT Tap*

From

 

Gas Meter

Approved Flexible Gas

(5" W.C.** to

Hose (if allowed by local

10.5" W.C.

codes)

Pressure)

Gas

 

 

Regulator

Tee Joint

 

Pipe

3" Minimum

Nipple

 

Cap

 

Sediment

Trap

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 23.

**Minimum inlet pressure for purpose of input adjustment.

Figure 14 - Gas Connection

Continued

10

103426

Page 10
Image 10
Desa 103426-01 installation manual Connecting To Gas Supply, Unvented Natural Gas Log Heater, Installation, Continued