INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.
CAUTION: To Avoid Fire Or Burn Hazards:
•Allow fi xture to cool before touching. The bulb and the fi xture operate at high temperatures.
•Keep fixture at least 1" (2.5 cm) from combustible ma- terials. Do not aim at objects closer than 3 ft. (1 m).
•Use only T3, 250W (max.) tungsten halogen 120 VAC lamps.
❒Note the position of the various parts of the fixture for the type of installation for your application and adjust the lamp head and sensor as shown below.
Wall Mount | Eave Mount |
Lens Retainer
Light Shield,
with opening at
this side
Lens Retainer
For under eave installation, the sensor head must be rotatedasshown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the Light Shield and stick on as shown below.
For eave mount only:
❒Swing the sensor head towards the clamp screw
joint.Controls Clamp Screw
❒Then rotate the sensor head clockwise 180° so the controls face down.
Controls
Light Shield
Opening
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
BULB INSTALLATION
❒When relamping, turn power off and let the fi xture cool.
❒Remove glass cover and remove the old bulb by pushing the bulb towards the socket indicated on the metal refl ector.
❒To insert the new bulb, follow the instructions printed on the metal refl ector.
❒Check that the bulb is seated properly.
❒Reinstall the glass cover.
WIRE THE LIGHT CONTROL
WARNING: Turn power off at circuit breaker or fuse.
❒Remove the existing light fi xture.
❒Install mounting strap to junction box using screws appropriate for your junction box.
❒The plastic hanger can be used to hold the fi xture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
❒Thread all fi xture wires through the large holes in the gasket as shown.
❒Connect the junction box wires to the light fi xture wires as shown.Twist together and secure with wire connectors.
Mounting Strap |
|
Black to Black | White to White |
| Rubber |
| Plug |
Mounting
Bolt
Gasket
Connectanyfixturegroundwire(s)andthecoverplate ground screw to the junction box ground wire.
MOUNT THE LIGHT CONTROL
❒Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.
❒Push the Rubber Plug fi rmly into place.
❒If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.