Desa RC70T Service Procedures, Wiring Diagrams, WARNING High Voltage, Continued, Replacing Fuse

Models: RC70T RC165CT BC55T BC70T RC115CT RC55T BC115CT BC165CT BC40

1 52
Download 52 pages 35.8 Kb
Page 15
Image 15
IGNITION CONTROL ASSEMBLY

SERVICE PROCEDURES

Continued

IGNITION CONTROL ASSEMBLY

 WARNING: High Voltage!Figure 29 - Replacing Fuse WARNING: High Voltage!

1.Unplug heater.

2.Remove side cover screws (4) using 5/16" nut-driver to expose ignition control assembly (see Figure 15 or 16, page 11).

3.Remove fuse cover (see Figure 29).

4.Remove fuse from fuse clips (see Figure 29).

5.Replace fuse with fuse of the same type and rating (GMA-10). Do not substitute a fuse with a higher current rating.

6.Replace fuse cover (see Figure 29).

7.Replace side cover (see Figure 15 or 16, page 11).

Fuse

Fuse

Clips

Cover

WIRING DIAGRAMSManual backgroundManual background Fuse

Figure 29 - Replacing Fuse

Ignition AssemblyControl

WIRING DIAGRAMS

Photocell

Blue

 

 

 

 

 

Photocell

Blue

Photocell

 

White

 

 

 

 

 

Ignitor

 

 

 

Motor Return

White

Green

 

 

 

AC Neutral (L2)

 

Green

Motor

 

 

120V (L1)

 

 

low

 

 

lYe

 

Red

 

Motor

 

 

Black

 

 

 

Ignitor

 

 

 

Power Plug 120V/60Hz

Assembly

 

 

Yel low

Ignitor

 

 

 

Figure 30 - Wiring Diagram for 40 Models

Photocell

Blue

 

 

 

 

 

Photocell

Blue

Photocell

 

White

 

 

 

 

 

 

Ignitor

 

 

 

ControlIgnition

Motor Return

AC Neutral (L2)

120V (L1)

Motor

Ignitor

White

Green

Power Plug

 

 

 

120V/60Hz

Green

Motor

 

Red

llowYe

Black

 

 

Black

 

Thermostat

 

 

Yellow

Ignitor

 

Figure 31 - Wiring Diagram for 55T/70T/115T/165T Thermostat Models

111168-01A

www.desatech.com

15

Page 15
Image 15
Desa RC70T Service Procedures, Wiring Diagrams, WARNING High Voltage, Continued, Ignition Control Assembly, Replacing Fuse