INSTALLATION

Continued

ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM

An outlet box with two receptacles (see Figure 9) has been supplied for your convenience and is located inside on the lower right side of the fireplace.

The remote control receiver is factory wired and connected to the convertible gas valve as shown in Figure 10.

Outlet Box

Three-prong Plug

Figure 9 - Duplex Outlet

The appliance must be isolated from the gas sup-

ply piping system by closing its individual shutoff

valve during any pressure testing of the gas supply

piping system at test pressures equal to or less than

1/2 psig (3.5 kPa).

 

 

The gas control valve is secured underneath the

firebox. Two 1/8" ports are provided on the gas

control valve for pressure test gauge connections

(see Figure 11).

 

 

 

Pilot Gas Line

 

 

Do Not Kink

To Pilot

Pilot Adjustment

Burner

ON/OFF

 

 

 

Knob

 

 

 

 

To Main

 

 

Burner

Inlet

Flame

 

Pressure Outlet

 

Adjustment Knob

Pressure

 

Figure 11 - Gas Control Valve

Convertible

 

Gas Valve

Remote

 

 

Control

 

Receiver

Figure 10 - Remote Control Receiver

GAS SUPPLY TESTING

NOTICE: This section is in-

tended as a guide for qualified

technicians installing gas to the

appliance.

WARNING: Do not connect

appliance before pressure test-

ing gas piping. Damage to gas

valve may result and an unsafe

condition may be created.

The appliance and its individual shutoff valve must

be disconnected from the gas supply piping system

during any pressure testing of that system at test

pressures in excess of 1/2 psig (3.5 kPa).

GAS LINE HOOK-UP

 

WARNING: Gas line hook-

up should be done by your gas

supplier or a qualified service

person.

 

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

 

An equipment shutoff valve has been included in

the fireplace's gas supply system. However, con-

sider installing an extra shutoff valve outside the

applianceʼs enclosure (check local codes), where

it can be accessed more conveniently with a key

through a wall as shown in Figure 12.

 

Key

Shutoff

 

 

Valve

Extension

Figure 12- Typical Exterior Wall Gas Shutoff Installation

111916-01F

www.desatech.com

9

Page 9
Image 9
Desa CD42M-A2, CD32M-2, CD36M-A1 Electrical Hookup and Remote Receiver Diagram, GAS Supply Testing, GAS Line HOOK-UP