CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.) Cabinet

SPECIFICATIONS

SERVICE HINTS

TECHNICAL SERVICE

CLEANING AND

MAINTENANCE

continued

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burners, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 33).

3.Blow air through the ports/slots and holes in the burners.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about twoinchesfromwherethepilotflamecomesoutofthepilotassembly(see Figure 34). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

Tube

Injector Holder

Primary Air

Inlet Holes

Figure 33 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot Assembly

Pilot Air

 

 

Inlet Hole

Figure 34 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

SPECIFICATIONS

 

CF26PT

CF26NT

Btu (Variable)

19,000/26,000

19,000/26,000

Type Gas

Propane/LP Only

Natural Only

Ignition

Piezo

Piezo

Manifold Pressure

8" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water) *

 

Maximum

14"

10.5"

Minimum

11"

5"

Dimensions, Inches (H x W x D)

 

Fireplace

25 7/8 x 27 x 13 3/4

25 7/8 x 27 x 13 3/4

Carton

28 x 26 13/16 x 16 1/2

28 x 26 13/16 x 16 1/2

Weight, pounds

 

 

Fireplace

44 1/2 lbs.

44 1/2 lbs.

Shipping

55 lbs.

55 lbs.

* For purposes of input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low (propane/LP only)

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web site at www.desatech.com.

For..com