CONNECTING TO GAS SUPPLY

Manual backgroundManual background CF26PR

VENT-FREE PROPANE/LP BAY FRONT FIREPLACE

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Manual background WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes.

Manual background CAUTION: Never connect fireplace directly to the propane/ LP supply. This fireplace re- quires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, fireplace regulator damage could occur. Install external regulator with

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

Manual background CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Propane/LP

Supply

Tank

External

Regulator

Vent

Pointing

Down

Figure 19 - External Regulator with Vent Pointing Down

We recommend that you install a sediment trap in supply line as shown in Figure 20 . Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

the vent pointing down as shown in Figure

19.Pointing the vent down protects it from freezing rain or sleet.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" or greater diameter to allow proper gas volume to fireplace. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 20).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

 

Gas

 

 

Control

CSA Design-Certified

 

 

Equipment Shutoff Valve

 

 

With 1/8" NPT Tap*

I

 

 

H

 

 

LO

 

 

O

 

N

F

 

O

F

 

TOL

P

 

Approved Flexible

Gas Hose

 

From External

 

Regulator

 

(11" W.C.** to

3" Minimum

14" W.C.

 

Pressure)

 

Cap Pipe

Tee

 

Nipple

Joint

 

 

 

Figure 20 - Gas Connection

Sediment Trap

 

 

 

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 28.

**Minimum inlet pressure for purpose of input adjustment.

For more information, visit www.desatech.com