OWNER’S MANUAL
OPERATING
HEATER
Continued
Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure.
8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 4 through 8.
9.Slightly push in and turn control
knob counterclockwise to the ON position.
10.Wait one minute and switch selector switch to the ON position to light burner.
11.Set flame adjustment knob to any level between HI and LO.
CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.
WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2a. Set selector switch in the OFF position
2b. If Using Optional
Shutting Off Burner Only (pilot stays lit)
You may shut off the burner and keep the pilot lit by doing one of the following:
1.Turn control knob clockwise to the PILOT position.
2.Use remote control manual OFF button.
3.Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Light- ing Instructions, page 16.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1.
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 28). Follow instructions included with the remote control.
Thermostat Control Operation
(Optional CGHRCT Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burner will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heat- ing system, etc.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. NOTE: The burner may light if
IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/ OFF buttons on the
CGHRC Operation:
2a. Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.
Pilot Burner | Ignitor |
| |
| Electrode |
| Control Knob in |
Flame Adjustment Knob | On Position |
ON
OFF REMOTE
L
IH
O
O
F F
PILO T
O
N
Figure 34 - Pilot
Selector Switch in Remote Position (Optional Remote Control)
Figure 35 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation