Desa CF26NRA, CF26PRA Continued, Built-Infireplace Installation, Minimum Clearance for

Models: CF26PRA

1 36
Download 36 pages 37.38 Kb
Page 9
Image 9
Figure 4 - Minimum Clearance for

INSTALLATION

Continued

An optional blower kit is available from your dealer. See Accessories, page 35. If planning to use blower, locate fireplace near an electrical outlet.

Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 4).

B.Clearances from the top of the fireplace open- ing to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves in- stalling fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. Follow the instructions below to install the fireplace in this manner. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 8, page 11.

Note: If desired, purchase a four-sided trim kit for built-in installations. See Accessories, page 35.

 

Actual

Framing

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

9 1/2"

10 1/2"

Bottom

3/4"

3/4"

1.Frame in rough opening. Use dimensions shown in Figure 5 for the rough opening.

If installing in a corner, use dimensions shown in Figure 6 for the rough opening. The height is 26 1/8" which is the same as the wall opening above.

2.An optional blower accessory is available (see Accessories, page 35). There are two options for connecting blower to electrical source.

Option one: Have a licensed electrician install a properly grounded, three-prong 120-volt electrical outlet at fireplace location. Locate outlet inside the framed enclosure. Blower power cord will plug into this outlet.

Option two: Have a licensed electrician con- nect blower to electrical source at junction box inside fireplace.

If using option one, have electrical outlet in- stalled at this time. If using option two, do not connect blower to electrical source at junction box until step 6.

3.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping.

4.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

5.Attach flexible gas line to fireplace gas regula- tor. See Connecting Fireplace to Gas Supply, page 16.

101/2"

267/8"

3/4" Off

The Floor

267/8"Combustible to Wall Minimum

Figure 5 - Rough Opening for Installing

in Wall

365/8"

257/8"

BUILT-IN FIREPLACE 267/8" Figure 5 - Rough Opening for Installing 513/4"

Figure 6 - Rough Opening for Installing

in Corner

113897-01A

www.desatech.com

9

Page 9
Image 9
Desa CF26NRA, CF26PRA Continued, Built-Infireplace Installation, Minimum Clearance for, Combustible to Wall