Desa CGB35N Inspecting Pilot And Burner Flame, Continued, see Troubleshooting, pages 26 through

Models: CGB50N CGB35N

1 40
Download 40 pages 49.28 Kb
Page 24
Image 24
•see Troubleshooting, pages 26 through 29.

INSPECTING PILOT AND BURNER FLAME

Continued

24

Sharp Blue

Flame

Figure 20 - Correct Burner Flame Pattern

High

Yellow

Flame

Flame

Lifting

Off of

Burner

Figure 21 - Incorrect Burner Flame Patterns

If burner flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 22)

see Troubleshooting, pages 26 through 29.