TECHNICAL

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

35,000 BTU/Hr

50,000 BTU/Hr

 

Model

Model

BTU

35,000

50,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3.5" W.C.

3.5" W.C.

Inlet Gas Pressure

 

 

Maximum

7" W.C.

7" W.C.

Minimum

5" W.C.

5" W.C.

Dimensions, Inches

 

 

Heater (H x W x D)

25 x 27 1/4 x 16

28 x 32 1/2 x 16

Shipping Weight (pounds)

78

98

Flue Vent Size

4" dia.

4" dia.

Orifice Size

34 drill, ø .111

29 drill, ø .136

Note: These heaters are certified for elevations of 0-4500 feet above sea level. For elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner will produce yellow flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

33

100351

Page 33
Image 33
Desa CGB50N, CGB35N installation manual Technical Service, Service Hints, Specifications

FAQ

What are the BTU specifications for the CGB35N and CGB50N models?

The CGB35N model has a BTU of 35,000, while the CGB50N model has a BTU of 50,000.

What type of gas are the heaters compatible with?

Both models are compatible with natural gas only.

What should I do if the pilot will not stay lit or if the burner has delayed ignition?

Contact your local natural gas supplier to check for low gas pressure or bad gas quality.