Desa Voltbattery Installation, CGD3924NR, CGB3924NR and CGB3930NR, Continued

Models: CGB3924NR CGB3930NR

1 28
Download 28 pages 6.63 Kb
Page 12
Image 12
9-VOLT BATTERY INSTALLATION

CGD3924NR, CGB3924NR and CGB3930NR

UVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 13).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to manual shutoff valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Manual

Open

Shutoff

 

Valve

 

Closed

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Fig- ure 13).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 15 through 17). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 16).

9-VOLT BATTERY INSTALLATION

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Alkaline Battery In Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt alkaline battery through the clip.

4.Attach the teminal wires to the battery.

Receiver

Figure 13 - Manual Shutoff Valve

Manual

Thermostat Gas Valve or

Shutoff

Control Valve Location

Valve

 

Gas Meter

Figure 14 - Checking Gas Joints

Terminal

Wires

9-Volt Battery

Figure 15 - Installing 9-Volt Battery In Receiver

Installing 9-Volt Battery In Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attack terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Cover

Remote

Control

Terminal

Unit

 

Wires

 

9-Volt

 

Battery

 

Manual background Battery

Housing

Figure 16 - Installing Battery In Hand-

Held Remote control Unit

12

104306

Page 12
Image 12
Desa Voltbattery Installation, CGD3924NR, CGB3924NR and CGB3930NR, Uvented Natural Gas Log Heater, Continued