CLEANING AND MAINTENANCE

OWNER’S MANUAL

OPERATING

HEATER

Continued

Shows Temperature Setting

 

 

HI

 

 

TEMP

Allows Burners to be

 

 

Turned On and Off with the

 

 

Hand-Held Remote Unit.

MAN

LO ON

The log heater will automatically

AUTO

OFF

cycle between pilot and the heat

 

 

setting that has been selected.

 

STATUS

 

 

Increases Room Temperature

Decreases Room Temperature

Turns Burners On and Off

Shows Current Operation Mode

CLEANING AND MAINTENANCE

INSPECTING WARNING: Turn off heater and let cool before cleaning.

PILOT FLAME PATTERN CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting,

Figure 28 - Thermostat Hand-Held Remote Control Unit Selections

pet hair, etc.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

Pilot Burner

Thermocouple

Figure 29 - Correct Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 30

turn heater off (see To Turn Off Gas to Appliance, page 16)

seeTroubleshooting, pages 18 through 20

Pilot Burner

Thermocouple

Figure 30 - Incorrect Pilot Flame Pattern

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

ODS/PILOT AND BURNER

Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to prop- erly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

BURNER PRIMARY AIR HOLE

Air is drawn into the burner through the 8 holes in the brass fitting at the burner en- trance. There holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean if needed. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

104306