TROUBLE- |
| OBSERVED | POSSIBLE |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||||
| PROBLEM | CAUSE | REMEDY |
| |||||||
SHOOTING |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |
| Burner does light | 1. | Burner orifice clogged | 1. | Clean burner (see |
| |||||
Continued |
|
| |||||||||
| after ODS/pilot is lit |
|
|
| Cleaning and Mainte- |
| |||||
|
|
|
|
|
| ||||||
|
|
|
|
|
| nance, page 23) or |
| ||||
|
|
|
|
|
| replace burner orifice |
| ||||
|
|
| 2. | Inlet gas pressure is | 2. | Contact local natural gas |
| ||||
|
|
|
| too low |
| company |
| ||||
|
|
| 3. | Burner orifice diameter | 3. | Replace burner orifice |
| ||||
|
|
|
| is too small |
|
|
|
|
|
|
|
|
|
| 4. | Thermopile leads | 4. | Reconnect leads (see |
| ||||
|
|
|
| disconnected or |
| Wiring Diagram, page |
| ||||
|
|
|
| improperly connected |
| 27) |
|
|
|
|
|
|
|
| 5. | Burners will not come | 5. | Replace battery in |
| ||||
|
|
|
| on in remote position |
| transmitter and receiver |
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
| Delayed ignition | 1. | Manifold pressure is | 1. | Contact local natural gas |
| ||||
|
| burner |
| too low |
| company |
| ||||
|
|
| 2. | Burner orifice clogged | 2. | Clean burner (see |
| ||||
|
|
|
|
|
| Cleaning and Mainte- |
| ||||
|
|
|
|
|
| nance, page 23) or |
| ||||
|
|
|
|
|
| replace burner orifice |
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
| Burner backfiring | 1. | Burner orifice is | 1. | Clean burner (see |
| ||||
|
| during combustion |
| clogged or damaged |
| Cleaning and Mainte- |
| ||||
|
|
|
|
|
| nance, page 23) or |
| ||||
|
|
|
|
|
| replace burner orifice |
| ||||
|
|
| 2. | Damaged burner | 2. | Replace damaged burner |
| ||||
|
|
| 3. | Gas regulator defective | 3. | Replace gas control |
| ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 1. | Not enough air | 1. | Check burner for dirt |
| ||||
|
| Slight smoke or |
|
|
| and debris. If found, |
| ||||
|
|
|
|
| clean burner (see |
| |||||
|
| odor during initial |
|
|
| Cleaning and Mainte- |
| ||||
|
| operation |
|
|
| nance, page 23) |
| ||||
|
|
| 2. | Gas regulator defective | 2. | Replace gas control |
| ||||
|
|
| 3. | Residues from manu- | 3. | Problem will stop after a |
| ||||
|
|
|
| facturing processes |
| few hours of operation |
| ||||
|
|
|
| and logs curing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| Moisture/condensa- | 1. Not enough combus- | 1. | Refer to Air for Com- |
| |||||
|
| tion noticed on |
| tion/ventilation air |
| bustion and Ventilation |
| ||||
|
| windows |
|
|
| requirements (page 5) |
| ||||
|
|
|
|
|
|
|
| ||||
|
| Heater produces a | 1. Turning control knob | 1. | Turn control knob to LO |
| |||||
|
| whistling noise |
| to HI position when |
| position and let warm up |
| ||||
|
| when burner is lit |
| burner is cold |
| for a minute |
| ||||
|
|
| 2. | Air in gas line | 2. | Operate burner until air |
| ||||
|
|
|
|
|
| is removed from line. |
| ||||
|
|
|
|
|
| Have gas line checked |
| ||||
|
|
|
|
|
| by local natural gas |
| ||||
|
|
|
|
|
| company |
| ||||
|
|
| 3. | Air passageways on | 3. | Observe minimum |
| ||||
|
|
|
| heater blocked |
| installation clearances |
| ||||
|
|
|
|
|
| (see pages |
| ||||
|
|
| 4. | Dirty or partially | 4. | Clean burner (see |
| ||||
|
|
|
| clogged burner orifice |
| Cleaning and Maintenance, |
| ||||
|
|
|
|
|
| page 23) or replace |
| ||||
|
|
|
|
|
| burner orifice |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Continued 25 |
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
103343