Desa CGD3924PR Volt Battery Installation, Pressure Testing Heater Gas Connections, Continued

Models: CGB3930PR CGB3924PR CGD3924PR

1 28
Download 28 pages 8.74 Kb
Page 12
Image 12
Pressure Testing Heater Gas Connections

CGD3924PR, CGB3924PR and CGB3930PR

UNVENTED PROPANE/LP GAS LOG HEATER

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Fig- ure 14).

2.Open propane supply tank valve.

3.Make sure control knob of heater is in the OFF position.

Manual

Shutoff Valve

Open

Closed

Figure 14 - Manual Shutoff Valve

4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 15 through 17). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 16).

9-VOLT BATTERY INSTALLATION

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Alkaline Battery In Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt alkaline battery through the clip.

4.Attach the teminal wires to the battery.

Propane Tank

Manual

Shutoff

Valve

Thermostat Gas Valve or

Control Valve Location

Receiver

Terminal

Wires

9-Volt Battery

Figure 16 - Installing 9-Volt Battery In Receiver

Installing 9-Volt Battery In Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attack terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Figure 15 - Checking Gas Joints

Battery Cover

Remote

Control

Terminal

Unit

 

Wires

 

9-Volt

 

Battery

 

9-VOLT BATTERY INSTALLATION Battery

Housing

Figure 17 - Installing Battery In Hand-

Held Remote control Unit

12

104307

Page 12
Image 12
Desa CGD3924PR, CGB3924PR, CGB3930PR Volt Battery Installation, Pressure Testing Heater Gas Connections, Continued