CGD3924PR, CGB3924PR and CGB3930PR
UNVENTED PROPANE/LP GAS LOG HEATER
INSTALLATION
Continued
Pressure Testing Heater Gas Connections
1.Open manual shutoff valve (see Fig- ure 14).
2.Open propane supply tank valve.
3.Make sure control knob of heater is in the OFF position.
Manual
Shutoff Valve
Open
Closed
Figure 14 - Manual Shutoff Valve
4.Check all joints from manual shutoff valve to control valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Light heater (see Operating Heater, pages 15 through 17). Check all other internal joints for leaks.
7.Turn off heater (see To Turn Off Gas to Appliance, page 16).
9-VOLT BATTERY INSTALLATION
Two
Installing 9-Volt Alkaline Battery In Receiver
1.Locate back of receiver under front burner of heater.
2.Locate the battery clip mounted on the back of the receiver.
3.Slide a
4.Attach the teminal wires to the battery.
Propane Tank
Manual |
Shutoff |
Valve |
Thermostat Gas Valve or |
Control Valve Location |
Receiver
Terminal
Wires
Figure 16 - Installing 9-Volt Battery In Receiver
Installing 9-Volt Battery In Hand- Held Remote Control Unit
1.Remove battery cover on back of re- mote control unit.
2.Attack terminal wires to the battery. Place battery into the battery housing.
3.Replace battery cover onto remote con- trol unit.
Figure 15 - Checking Gas Joints
Battery Cover | Remote |
Control | |
Terminal | Unit |
| |
Wires |
|
| |
Battery |
|
Battery
Housing
Figure 17 - Installing Battery In Hand-
Held Remote control Unit
12 | 104307 |