OWNER’S MANUAL
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
NOTICE: A qualified service per- son must install heater. Follow all local codes.
NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.
WARNING: Make sure the re- mote selector switch is in the OFF position before installing heater.
WARNING: Never install the heater
•in a bedroom or bathroom
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
•in high traffic areas
•in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
IMPORTANT:
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Rear
Width
LogFront At 14"
Size Height Depth Width Depth
24" | 17" | 14" | 28" | 21" |
30" | 17" | 14" | 34" | 24" |
Carefully follow the instructions below. This will ensure safe installation into a masonry fireplace or
Minimum Wall and Ceiling Clearances (see Figure 4)
A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
42"
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.
WARNING: Seal any fresh air vents or ash
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION AND
CLEARANCES (Vent-Free
Operation Only)
WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.
16"
Left and
Right Sides
Figure 4 - Minimum Clearance to Wall and Ceiling
cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size | Side Wall | Ceiling |
|
|
|
24" | 16" | 42" |
Continued
104307 | 7 |