OWNER’S MANUAL

INSTALLATION

Continued

MANTEL CLEARANCES

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clear- ances shown in Figure 7 when using hood.

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

 

 

 

 

12"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

24" Log Set

24"/30" Models

Top of Fireplace

Opening

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the

 

flue damper open

raise the mantel to an accept-

 

able height

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

• remove the mantel.

Floor Clearances

A.If installing appliance on the floor level, you must maintain the minimum dis- tance of 14" to combustibles (see Fig- ure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combus- tible flooring (see Figure 9).

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

 

 

 

2 1/2"

 

 

Minimum Non-

 

 

 

Combustible

 

 

 

Material

8"

12"

15"

 

 

Min.

 

 

 

Hood

Distances to

 

(GA6050, GA6052)

 

Underside of

 

 

 

 

Mantel

18"

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

20" All Models

Top of Fireplace Opening

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

 

 

14"

Material

Hearth

Combustible

Min.

 

 

 

 

 

5"

Material

Non-Combustible

Min.

 

 

Material

 

 

Figure 9 - Minimum Fireplace Clearances

Figure 8 - Minimum Fireplace Clearances Above Combustible Flooring If Installed at Floor Level

Continued

104307

9

Page 9
Image 9
Desa CGD3924PR, CGB3924PR, CGB3930PR installation manual Mantel Clearances, Floor Clearances