INSTALLATION
Continued
We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.
CSA Design- |
| |
Certified Equipment |
| |
Shutoff Valve With |
| |
1/8" NPT Tap* | Propane/LP | |
| ||
| From External | |
| Regulator (11" | |
| W.C.** to 14" | |
| W.C. Pressure) | |
Approved | Natural | |
Flexible Gas | ||
From Gas Meter | ||
Line | ||
(5" W.C.** to | ||
| ||
| 10.5" W.C. | |
3" Minimum | Pressure) | |
|
Pipe Nipple Cap Tee Joint
Sediment Trap
Figure 14 - Gas Connection
* Purchase the optional CSA |
1.Route flexible gas line, included, from fire- place control to equipment shutoff valve through side or rear access holes in outer casing (see Figure 1, page 5).
2.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/ equipment shutoff valve (see Figure 15).
CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings
CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings
3.Check all gas connections for leaks. See
Checking Gas Connections.
4.Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area.
To Gas Regulator
Valve (Remote-
Ready Models) Equipment
Shutoff Valve
equipment shutoff valve from your dealer. See |
Accessories, page 34. |
CONNECTING Fireplace to Gas Supply
Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not
Flexible Gas Line from Fireplace Gas Regulator Provided
With Fireplace
Propane/LP
To External
Regulator
Natural
To Gas Supply
provided)
NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow acces- sibility from the fireplace (see Figure 1, page 5). The flexible gas supply line connection to the equipment shutoff valve should be accessible.
Figure 15 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
14 | www.desatech.com |