Cleaning and
Maintenance
Continued
Pilot Air
Inlet Hole
Pilot Assembly
Figure 41 - Pilot Inlet Air Hole
(Propane/LP Gas)
Pilot Air
Inlet Hole
Pilot Assembly
Figure 42 - Pilot Inlet Air Hole
(Natural Gas)
LOG Set
•If you remove
•Replace log set if broken or chipped
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
Troubleshooting
WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
|
|
|
| |
When ignitor button is pressed, | 1. Ignitor electrode not con- | 1. | Reconnect ignitor cable | |
there is no spark at ODS/pilot | 2. | nected to ignitor cable | 2. | Free ignitor cable if pinched |
| Ignitor cable pinched or wet | |||
|
|
|
| by any metal or tubing. Keep |
| 3. | Broken ignitor cable | 3. | ignitor cable dry |
| Replace ignitor cable | |||
| 4. | Bad ignitor | 4. | Replace ignitor |
| 5. | Ignitor electrode positioned | 5. | Replace pilot assembly |
| 6. | wrong | 6. | Replace pilot assembly |
| Ignitor electrode broken | |||
| 7. | Battery not installed, battery | 7. | Install new alkaline battery in |
|
| power low or battery not |
| electronic ignitor. Verify bat- |
|
| installed correctly |
| tery is installed correctly |
www.desatech.com | 25 |