Desa VGMRP Installation, Checking Gas Connections, Pressure Testing Gas Supply Piping System

Models: VGMRN VGMRP CGMFN CGMFP

1 36
Download 36 pages 22.81 Kb
Page 15
Image 15
CHECKING GAS CONNECTIONS

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

Pressure Testing Gas Supply WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

Test Pressures In Excess Of 1/2 PSIGWARNING:Neveruseanopen flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles form- ing show a leak. Correct all leaks at once.

Test Pressures Equal To or Less Than CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and fireplace. See guidelines under Connecting to Gas Sup- ply, page 13.

Pressure Testing Gas Supply

Piping System

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks.

Test Pressures Equal To or Less Than

1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 16).

2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3. Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figures 17 or 18). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Equipment

Open

 

Shutoff Valve

 

Closed

Figure 16 - Equipment Shutoff Valve

Equipment

Gas Valve

Shutoff Valve

 

Propane/LP

 

Supply Tank

 

Figure 17 - Checking Gas Joints

(Propane/LP Only)

Gas Regulator or

Equipment Gas Control Valve Shutoff Valve

Gas

Meter

Figure 18 - Checking Gas Joints (Natural

Gas Only)

119315-01A