Desa CRL3124P Installing Logs, Installation, Continued, Pressure Testing Heater Gas Connections

Models: CCL3018PT CGD3924PT CGD3930P CGD3930PT CCL3924P CCL3924PT CCL3930PTA CGD3018PT CGD3924P CCL3018P CRL3124P CRL2718P

1 44
Download 44 pages 1.86 Kb
Page 13
Image 13
INSTALLING LOGS

INSTALLATION

Checking Gas Connections (Cont.) Installing Logs

13

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 17).

2.Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP supply tank to equipment shutoff valve (see Figure 18). Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

INSTALLING LOGS

Pressure Testing Heater Gas ConnectionsCAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to high, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Pressure Testing Heater Gas Connections

1.

Open equipment shutoff valve (see Figure 17).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in the OFF position.

4.

Check all joints from equipment shutoff valve to control valve

 

(see Figure 18). Apply a noncorrosive leak detection fluid to

 

all joints. Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater, pages 19 and 20 [manu-

 

ally-controlled models] or pages 20 and 21 [thermostatically-

 

controlled models]). Check all other internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to Appliance, page 20

 

[manually-controlled models] or page 21 [thermostatically-con-

Dual Burner Smoky Mountain Oak Models

Dual Burner Smoky Mountain Oak Models WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pins on the bottom of back log (#1). Slide these pins into the holes in the grate base behind the burner (see Figure 19).

trolled models]).

Open

Pin

Back Log Manual background (#1)

Equipment

Shutoff

Valve

Closed

Figure 17 - Equipment Shutoff Valve

Hole in Grate Base

Propane/LP Supply Tank

Equipment

Shutoff Valve

Thermostat Gas Valve or

Control Valve Location

Burner

Figure 19 - Installing Back Log (#1)

Figure 18 - Checking Gas Joints

For moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

107124-01E

Page 13
Image 13
Desa CRL3124P, CRL2718P, CCL3018P Installing Logs, Installation, Continued, Pressure Testing Heater Gas Connections