OPERATING HEATER
Lighting Instructions
To Turn Off Gas to Appliance
21
OPERATING HEATER
Continued
LIGHTING INSTRUCTIONS
WARNING
•If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.
•You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.
NOTICE: During initial operation of new heater, burning logs will give off a
Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been running.
6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 22.
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.
8.Turn control knob counterclockwise
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
HI
| OFF |
OL | Pilot |
|
Ignitor Button | Control Knob |
Figure 41 - Control Knob and Ignitor Button Location
1.STOP! Read the safety information, page 20, column 2.
2.Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 20, column 2. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 41).
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.
Ignitor | Pilot Burner |
Electrode |
|
Thermocouple
Figure 42 - Pilot
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise Clockwise to the OFF position.
Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise Clockwise to the PILOT position.
For morevisit www..com