Desa EFS33NRB Safety Information, Product Identification, Continued, Fireplace VSGF33NRB Shown

Models: VSGF33PRB EFS33PRB VSGF33NRB EFS33NRB

1 36
Download 36 pages 370 b
Page 4
Image 4
Continued

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) in- side any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bed- room or bathroom.

5.Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, pages 21 and 22.

8.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

9.This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if enough fresh air is not available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Troubleshooting, pages 23 through 26.

10.Do not run fireplace

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this fireplace to cook food or burn paper or other objects.

12.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

13.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

14.Turn fireplace off and let cool before servic- ing. Only a qualified service person should service and repair fireplace.

15.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems in pro- pane/LP units, do not use propane/LP fuel tanks of less than 100 lbs. capacity (pro- pane/LP units only).

17.Provide adequate clearances around air openings.

PRODUCT

IDENTIFICATION

Rear Log

 

Middle Log

Rear

Front

Burner

Log

 

Piezo

 

Ignitor

 

Front

 

Burner

 

Optional

 

Remote Control

Base Assembly

Figure 1 - Log Base Assembly

(VSGF33NRB Shown)

Top Outer Casing

Fireplace

Top Louver

Hood

Assembly

 

Firebox

 

Support

Optional

 

Blower

 

Assembly

 

(Not

 

Included)

 

Bottom

Screen

Louver

Assembly

Assembly

Figure 2 - Fireplace (VSGF33NRB Shown)

4

www.desatech.com

113132-01A

Page 4
Image 4