Desa VSGF33NRB Continued, Built-Infireplace Installation, Inserting Fireplace Into, in Corner

Models: VSGF33PRB EFS33PRB VSGF33NRB EFS33NRB

1 36
Download 36 pages 370 b
Page 11
Image 11
Figure 12 - Inserting Fireplace Into

INSTALLATION

Continued

11.Carefully insert fireplace into cabinet mantel. Be careful not to scratch or damage hearth base, cabinet mantel, or any laminate trim on hearth base. Remove protective material from top of hearth base and from front of fireplace (if any). Note: You can secure fireplace to hearth or floor. Open lower louver. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or floor.

12.Check all gas connections for leaks. See Checking Gas Connections, pages 15 and 16.

3.Install gas piping into fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equip- ment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Loca- tion, pages 12 and 13.

4.Carefully set fireplace in front of rough open- ing with back of fireplace inside wall opening.

5.Carefully insert fireplace into rough opening.

6.Attach flexible gas line to gas supply. See Connecting Fireplace to Gas Supply, page 14.

7.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 15).

8.Check all gas connections for leaks. See Checking Gas Connections, pages 15 and 16.

9.Plug electrical cord into electrical outlet in- stalled in step 2.

10.Install trim after final finishing and/or paint- ing of wall (see Figure 7, page 9).

Figure 12 - Inserting Fireplace Into

Cabinet Mantel

BUILT-IN FIREPLACE

INSTALLATION

Built-in installation of this fireplace involves in- stalling fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If in- stalling a mantel above the fireplace, you must fol- low the clearances shown in Figure 16, page 12. Follow the instructions below to install the fire- place in this manner.

 

Actual

Framing

 

 

 

Height

32 3/8"

33"

Front Width

34 5/16"

35 1/2"

Depth

16 11/16"

17 3/4"

1.Frame in rough opening. Use dimensions shown in Figure 13 for the rough opening. If installing in a corner, use dimensions shown in Figure 14 for the rough opening. The height is 33" which is the same as the wall opening above.

2.If using blower, install and properly ground GA3555, three-prong 120 volt electrical outlet, in fireplace. Follow instructions included in kit.

17 3/4"

33"

Cabinet MantelBUILT-IN FIREPLACE 35 1/2" Figure 13 - Rough Opening for Installing

Figure 13 - Rough Opening for Installing

in Wall

393/8"

27 7/8"

Figure 14 - Rough Opening for Installing 35 1/2" in Corner 55 5/8"

Figure 14 - Rough Opening for Installing

in Corner

Nails or Wood

Screws

Nailing

Flanges

Figure 15 - Attaching Fireplace to Wall

Studs

113132-01A

www.desatech.com

11

Page 11
Image 11
Desa VSGF33NRB, EFS33NRB Continued, Built-Infireplace Installation, Inserting Fireplace Into, Cabinet Mantel, in Corner