14
OPERATING HEATER
For Your Safety Read Before Lighting Lighting Instructions
OPERATING HEATER
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire de- partment.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
1.STOP! Read the safety information above.
2.Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position (see Figure 26 or 27).
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step.
5.Press in control knob and turn counterclockwise
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.
•If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
6.With control knob pressed in, push down and release igni- tor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to Troubleshooting, pages 18 through 20. Also contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with a match. To light pilot with amatch, see Manual Lighting Procedure, page 15.
7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
•If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3 through 7. Thermo- stat model heaters have a safety interlock system. Wait one
(1) minute before lighting pilot again.
8.Manual Controlled Models Only Turn control knob coun-
terclockwise
Note: Both HI and LO are locked positions. You must press in control knob before turning it from these positions.
9.Thermostat Controlled Models Only Turn control knob
counterclockwise
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Ignitor Button | Ignitor Button | Control Knob |
Control Knob |
| |
|
| |
|
| FO |
Figure 26 - Control Knob In | Figure 27 - Control Knob In | |
The OFF Position (Manual | The OFF Position (Thermostat | |
Controlled Models) | Controlled Models) |
Thermocouple
Ignitor Electrode
Pilot Burner
Figure 28 - Pilot
For morevisit www..com