VENTILATION AIR

6

AIR FOR COMBUSTION AND VENTILATION

Ventilation Air

INSTALLATION

Check Gas Type

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

Ventilated

Outlet Attic

Air

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 18" (45 cm) of the ceiling and one within 18" (45 cm) of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow CAN/CGA B149.1 Natural Gas Installation Code or CAN/ CGA B149.2 Propane Installation Code for required size of venti- lation grills or ducts.

Outlet Ventilation Air From Inside Building Air

Inlet

Air

To Attic

To

Crawl

Space

Inlet Air

 

Ventilated

 

Crawl Space

 

 

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 18" (45 cm) of the ceiling and one within 18" (45 cm) of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow CAN/CGA B149.1 Natural Gas Installation Code or CAN/CGA B149.2 Propane Installation Code for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

Installation must conform with local codes or, in the absence of local codes, with the current standard CAN/CGA B149.1 Natural Gas Installation Code or CAN/CGA B149.2 Propane Installation Code

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

18"

12" (45 cm)

Ventilation Grills

Into Adjoining Room,

Option 2

primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Ventilation Air From Outdoors WARNING: A qualified service person must in- stall heater. Follow all local codes.

CHECK GAS TYPE

18"

12"

(45 cm)

Figure 2 - Ventilation Air from Inside Building

INSTALLATIONCHECK GAS TYPEManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater. Call dealer where you bought heater for proper type heater.

visit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

112157-01A

Page 6
Image 6
Desa GCN6 Installation, Check Gas Type, Ventilation Air From Inside Building, Ventilation Air From Outdoors, Continued