Desa LFP33PR Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, foreign matter

Models: LFP33PR

1 30
Download 30 pages 51.56 Kb
Page 21
Image 21
ing Gas Connections, page 12)

OWNER’S MANUAL

TROUBLESHOOTING

Continued

Take apart gas tubing and remove WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (see IMPORTANT statement

 

 

above)

 

2.

Gas leak. See Warning statement

 

 

above

1.Open window and ventilate room. Stop using odor causing products while fire- place is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventila-

 

 

 

 

tion

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, page 12)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

1.

Take apart gas tubing and remove

 

 

and burner

 

foreign matter

 

2.

Gas leak. See Warning statement

2.

Locate and correct all leaks (see Check-

 

 

above

 

ing Gas Connections, page 12)

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

 

2.

Drafts or other air currents affecting

 

page 13)

 

2.

Eliminate source of drafts around heater

 

 

flame pattern

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlets. Pe-

 

4.

Burner flame holes blocked

 

riodically repeat as needed

 

4.

Remove blockage or replace burner

www.desatech.com

104888

21

Page 21
Image 21
Desa LFP33PR Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, Maintenance, page, foreign matter