Desa LFP33PRA installation manual Connecting Fireplace To Gas Supply, Installation, Continued

Models: LFP33PRA

1 30
Download 30 pages 3.63 Kb
Page 11
Image 11
CONNECTING FIREPLACE TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 17. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sedi- ment trap is not installed or is installed wrong, fireplace may not run properly.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.

2.Remove screws that attach log base assembly to fireplace (see Figure 18). Carefully lift up log base assembly and remove from fireplace (see Figure 18).

Manual background CAUTION: Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.

3.Route gas line (provided by installer) from equipment shutoff valve to fire- place. Route flexible gas supply line through one of the access holes.

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility from the fireplace (see Figure 19). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

4.Attach the flexible gas line to gas sup- ply (see Figure 19). Check tightness of flexible gas line attached to gas regu- lator of fireplace (see Figure 19).

5.Check all gas connections for leaks. See Checking Gas Connections, page 12.

6.Replace log base assembly back into fireplace. Feed flexible gas line into fire- place base area while replacing log base assembly. Make sure the entire flexible gas line is in fireplace base area. Reat- tach log base assembly to fireplace with screws removed in step 2.

CSA Design-

Certified Equipment

Shutoff Valve With

1/8" NPT Tap*

 

From

 

External

 

Regulator

 

(11" W.C. to

3" Minimum

14 " W.C.

Pressure

Pipe Cap Tee

Nipple Joint

Sediment Trap

Figure 17 - Gas Connection

*Purchase the optional CSA design-certi- fied equipment shutoff valve from your dealer. See Accessories, pages 24 and 25.

To Fireplace

Flexible Gas

Gas Regulator

Line from

Fireplace Gas

 

 

Regulator

Equipment

To

Shutoff Valve

Provided by

External

Installer

Regulator

Figure 19 - Attaching Gas Lines Together

Figure 18 - Removing Log Base Assembly

From Fireplace

Continued

107064

11

Page 11
Image 11