Desa LFP33PRA installation manual Wiring Diagram, Service Hints, Specifications, Technical Service

Models: LFP33PRA

1 30
Download 30 pages 3.63 Kb
Page 22
Image 22
WIRING DIAGRAM

LFP33PRA

UNVENTED PROPANE/LP GAS FIREPLACE

WIRING DIAGRAM

Note: For proper operation of optional ac- cessories, the wires from the switch to the control must be connected exactly as shown.

AUTOSERVICE HINTS

OFF

ON

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

Thermopile

SPECIFICATIONS

LFP33PR Remote Ready

 

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

8.0" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

Minimum*

11"

Shipping Weight

30 lbs. (24")/32 lbs.

 

(30")/34 lbs. (36”)

* For input adjustment

 

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

You can also visit DESA International’s technical service web site at www.desatech.com.

22

107064

Page 22
Image 22
Desa LFP33PRA Wiring Diagram, Service Hints, Specifications, Technical Service, When Gas Pressure Is Too Low