Desa RLP100 owner manual Service Procedures, Motor, Location of Ground Screw

Models: RLP100

1 32
Download 32 pages 34.9 Kb
Page 8
Image 8
SERVICE PROCEDURES

SERVICE PROCEDURES

MOTOR WARNING: Never service heater while it is plugged in, connected to propane supply, operating or hot. Severe burns and electrical shock can occur.

MOTOR

1.With heater on its side, remove base tray.

2.Access ground screw through underside of heater base. Remove ground screw. Disconnect the green motor wire and the green power cord wire from underside of shell (see Figure 5).

3.Remove black and white motor wires from terminal board (see Figure 5).

4.Carefully push motor wires through hole in bottom of shell.

5.Remove screws holding motor mount to shell. Use nut-driver (see Figure 6).

6.Carefully pull motor and fan out of shell. IMPORTANT: Be careful not to damage fan. Do not set motor and fan down with the weight resting on fan. This could damage fan pitch.

7.Use hex wrench to loosen setscrew which holds fan to motor shaft.

8.Remove fan. Be careful not to damage the fan blade pitch.

9.Use nut driver to remove two nuts that attach motor to motor mount.

10.Discard old motor.

11.Attach motor to motor mount with two nuts. Tighten nuts firmly.

12.Replace fan on motor shaft. Make sure set screw contacts flat surface on motor shaft.

13.Tighten set screw firmly (40-50 inch-pounds [46.08-57.60 kilogram-centimeters]).

 

Transformer

Ground Screw

Green Lead

Motor

Power

Green

Cord

Lead

Green

 

Lead

14.Carefully route motor wires through hole in shell (see Figure 7). Place motor, motor mount and fan guard into rear of heater shell.

15.Insert screws through heater shell and into motor mount. Tighten screws firmly.

16.Turn heater on its side to access opening in bottom of base. Connect green wires from motor, transformer and power cord to heater shell using ground nut (see Figure 5).

17.Attach black and white wires to terminal board (see Wiring Diagram, page 11, for correct locations) .

18.Replace base tray.

Motor

Mount

Screw

Fan

Guard

Motor

Mount

Hole in Shell for Wires

Figure 6 - Removing Motor, Motor Mount and Fan Guard from Heater

Hole in Figure 5 - Location of Ground Screw

Shell for

Wires

Figure 7 - Replacing Motor, Motor Mount and Fan Guard into Heater

Terminal

Board

Figure 5 - Location of Ground Screw

8

www.desatech.com

111710-01B

Page 8
Image 8
Desa RLP100 owner manual Service Procedures, Motor, Location of Ground Screw