SERVICE PROCEDURES
Continued
FAN
1Remove motor, motor mount and fan (see Motor, steps 1 through 8, page 8).
2.Clean fan using soft cloth moistened with kerosene or solvent.
3.Dry fan thoroughly.
4.Replace fan on motor shaft. Make sure set- screw is touching back of flat surface on motor shaft (see Figure 8).
5.Place setscrew on flat of shaft. Tighten set- screw firmly
6.Place motor, motor mount and fan guard into rear of heater shell (see Motor, steps 14 through 18, page 8).
Fan Setscrew
SPARK TRANSFORMER
1.Remove base tray.
2.Locate and disconnect white, black and orange wires from spark transformer.
3.Remove two screws holding spark trans- former to base. Remove sheet metal nuts on transformer and install on new transformer. Discard spark transformer.
4.Install new spark transformer. Position new spark transformer in same manner as old transformer.
5.Connect white, black and orange wires to new spark transformer. Connect wires to correct terminals as noted in step 2.
6.Replace base tray.
Ignitor Wire
Bushing
Motor Shaft
Figure 8 - Fan, Motor Shaft and Setscrew
Location
Figure 10 - Removing Ignitor Wire from Spark Transformer
Fan
Hub
Motor
Shaft
Setscrew
Figure 9 - Fan Cross Section
www.desatech.com | 9 |