Canopy T1/E1 Multiplexer

September 2004

 

T1/E1 Multiplexer FPGA Version 3.4

3.5MEASUREMENTS FROM DIAGNOSTICS

Aunit-based comparison of diagnostic measurements is provided in Table 13.

Table 13: Comparison of diagnostic measurements

Measurement

Description

Availability

Advantage

Disadvantage

 

 

 

 

 

Bit errors

Logic errors in

Only out of

Best unit for

Requires that all traffic

 

the bit stream

service

point-to-point

be test traffic (known

 

 

 

performance

data pattern)

BPVs

Pulses of the

In service

Good for circuit

Meaningful for only

 

same consecutive

or out of

or repeater

metallic media, because

 

polarity

service

problems

some equipment corrects

 

 

 

 

BPVs

 

 

 

 

 

Frame errors

Incorrect values

In service

Approximates

Evaluates only overhead

 

in the framing

or out of

bit error rate on

bits

 

bit position

service

in-service basis

 

 

 

 

 

 

CRC errors

Bit errors in a

In service

98.4% bit error

Available with only ESF

 

block of data

or out of

rate accuracy

framing

 

 

service

 

 

 

 

 

 

 

3.6FIRMWARE UPGRADES

Firmware upgrades are periodically made available to enhance performance or to add features and functionality to the Canopy T1/E1 Multiplexer.

Procedure 29: Upgrading firmware

To install new firmware on a Canopy T1/E1 Multiplexer, perform the following steps.

1.Close any other applications that are active on the PC.

2.From the main menu of the EMS, select Config→Software Upgrade (shown in Figure 15 on Page 33).

RESULT: The System Upgrade window opens, as shown in Figure 24.

Figure 24: System Upgrade window

Issue 3

Page 59 of 73

Page 59
Image 59
Motorola T1/E1 manual Measurements from Diagnostics, Firmware Upgrades, Comparison of diagnostic measurements